跳至正文
测试版

这是全新的NaturalRefrigerants.com。如发现技术或内容问题,请发送邮件至info@naturalrefrigerants.com。

OCS Cold

Pumped Liquid Accumulator/Receiver

本产品页面暂无中文版本 — 显示英文原文。

Pumped Liquid Accumulator / Receiver

图01 — Pumped Liquid Accumulator / Receiver

01 概览

OCS COLD presents a CO₂ pumped liquid accumulator/receiver designed with the use of a series of calculation software, which keep in consideration a series of parameters and thermodynamic variables that allow to select the component and calculate the performances with high accuracy.

01

This Pumped Liquid Accumulator/Receiver from OCS Cold has the function as accumulator tank for the liquid CO2 that feeds the pumps and also, as a liquid separator, to accumulate the excess of liquid coming back from the flooded evaporators in order to allow the suction of only saturated CO2 vapors to the compressors.

  • Normalized and highly resilient carbon steels
  • Welding connections and the manufacturing features customized according customer’s needs
  • IN and OUT connections calculated and designed in order to optimize the performances of the refrigerating system, based on optimal velocities and with very low pressure drops, with particular attention to the protection of the compressors from any return of liquid on the suction line. Gas and liquid result perfectly separated inside the pumped receiver
  • Nr. 3 internal heat exchangers of adequate length, configuration and thickness which are used by the backup refrigeration Rack, that maintains the internal pressure at very low values during the time in which the compressors are in standby. The internal exchangers work as evaporators in parallel. They have been designed in order to have very low pressure drops and adequate exchange surfaces, and sized to be able to manage even very high thermal loads during standstill
  • Inside of the Pumped Liquid Accumulator/Receiver are installed small little pipes with calibrated holes mounted at a proper height where the oil has the tendency to accumulate. Their sizing selection has taken into account the difference of density between the refrigerant at subcritical temperature and the oil so, thanks to these pipes, is possible to reach the recovery of an high percentage of oil and send it to the recovery heat exchangers. This takes to minimize the use of the oil in the oil receiver, and ensure the functionality in safe conditions for the compressors of the refrigerating system
  • The component can be supplied with a level cylinder with capacitive device, in order to monitor the liquid level, and its floating movements, during the various operating conditions of the system.

02 技术资料

技术规格

9项数据 · 由OCS Cold发布

制冷剂
A1 and A2/A2L
Operating pressure
30-60bar

01性能

1项

Pump down capacity
On request

02运行范围

2项

Operating pressure
30-60 bar
Temperature range
-46 °C to 140 °C

03制冷剂

2项

Refrigerant
A1 and A2/A2 L
Refrigerant
CO₂

04结构与尺寸

2项

Height/diameter
6000 mm/1200 mm
Volume
750 to 5000 L

05认证与市场

2项

Region
Europe, South America
Certification
CE and EAC
OCS COLD Srl logo

就Pumped Liquid Accumulator/Receiver联系OCS Cold。

向OCS Cold发送询价 — 可就贵项目咨询技术规格、价格和供货情况。

分享