Dry Coolers with Adiabatic Cooling Options

Dry Coolers are used in cooling of process water with ambient air and can be customized for different operating conditions and capacity requirements.

本产品页面暂无中文版本 — 显示英文原文。

Dry Cooler Adiabatic Image

图01 — Dry Cooler Adiabatic Image

01 概览

To increase dry capacity, adiabatic cooling utilizes the latent heat of water, maintaining cooling performance even under high ambient temperatures. Depending on project requirements, cooling support can be provided by a water spraying nozzle system, an adiabatic pad system, or hybrid systems combining both solutions for flexible and efficient operation. KARYER Dry Coolers are available in V-type, vertical, and horizontal configurations and can be manufactured in lengths of up to 12 meters. Depending on project needs, up to 18 double-row fans can be designed, with fan diameters ranging from Ø500 mm to Ø910 mm. Coils can be manufactured with copper or stainless steel tubes and aluminum fins, with corrosion-resistant coating options available.

01

In this case, different cooling support systems are available. With the water spraying nozzle system, water is sprayed around the product to reduce the temperature of the inlet air. By lowering the inlet air temperature through evaporative cooling, the system helps maintain cooling capacity during peak temperature periods.

Alternatively, Adiabatic pad system uses wetted pads positioned around the product to pre-cool the incoming air. As the air passes through the moistened pads, its temperature is reduced by adiabatic cooling, allowing the Dry Cooler to operate more efficiently.

02

In addition, hybrid systems combining both adiabatic pads and water spraying can be applied. These systems can be operated separately according to capacity demand, ensuring flexibility, optimized water usage, and efficient operation.

KARYER Dry Coolers can be manufactured in lengths of up to 12 meters and are available in V-type, vertical, and horizontal configurations. Depending on project needs, up to 18 double-row fans can be designed. The fan diameters of the dry cooler models range from Ø500 mm to Ø910 mm. The V-type structure allows space saving in installation areas, making it an ideal solution for factories, thermal power plants, and cogeneration systems. Each product is designed by considering meteorological conditions, installation location, available water supply, water softening possibilities, and site constraints.

03

The coils can be manufactured with either copper or stainless steel tubes and aluminum fins, depending on application requirements. Two coating options are available: pre-coated fin options and coating for high protection against corrosion.