Vai al contenuto
Beta

Questo è il nuovo NaturalRefrigerants.com. Hai notato un problema tecnico o di contenuto? Scrivici a info@naturalrefrigerants.com.

Compact Kältetechnik GmbH

Compact Ejector

Compact Ejector is used to increase efficiency in CO₂ booster systems.

Questa scheda prodotto non è ancora disponibile in italiano: viene mostrato l’originale in inglese.

Compact Logo

Compact Kältetechnik GmbH

Profilo aziendale
Compact Enjector

Fig. 01 — Compact Enjector

01 Panoramica

In conjunction with a high-pressure valve, three different types of gas and two types of liquid ejectors can be combined as desired.

01

Features

  • Efficiency increases of 15-30% possible (compare with a booster system with flash gas bypass)
  • Lower compressor capacity required (smaller or fewer number of compressors)
  • Can be individually tailored to each application and each performance level
  • Air conditioning and/or heat pump evaporator can be integrated
  • Extended running time of the parallel compressor even at lower outside temperatures
  • High reliability (no moving or rotating components)
  • Short payback period (depending on system size)

Function – Principle of operation
* c -Ejector uses the expansion work present in the refrigerant to suck in another partial flow and transport it to a higher pressure level.

The CO₂ emerging from the gas cooler at high pressure is accelerated in the motive nozzle. As a result, the static pressure drops. The flow emerging from the motive nozzle has a lower pressure than the suction pressure of the NK stage.

02

Either gas or liquid can be extracted from the suction side of the NK compressors.

Both partial streams mix in the mixing chamber.

03

In the diffuser, the flow is slowed down again, which causes a pressure increase to medium pressure level. After the diffuser, the mixture is fed into the medium pressure separator.

02 Scheda tecnica

Specifiche

8 dati · come pubblicati da Compact Kältetechnik GmbH

Refrigerante
CO₂
Max. working pressure
120bars

01Limiti di funzionamento

4 voci

Max. working pressure
120bars
Test pressure
1.1 x 120 bar
Temperature medium
-50 °C … +150 °C
Temperature Ambient
-10 °C … +50 °C

02Refrigerante

1 voce

Refrigerant
CO₂

03Costruzione e dimensioni

2 voci

Material
Stainless steel 1.4301
Weight
1.3 kg

04Certificazioni e mercati

1 voce

Region
Europe
Compact Logo

Parla con Compact Kältetechnik GmbH del prodotto Compact Ejector.

Invia la tua richiesta a Compact Kältetechnik GmbH: chiedi specifiche, prezzi e disponibilità per il tuo progetto.

Condividi