Evapco
LCR-P Penthouse
The Evapcold LCR-P product line is based on a penthouse configuration and includes 250 models that have an ammonia charge ranging from 2 to 6 lbs. per TR.
Cette page produit n’est pas encore disponible en français : l’original en anglais est affiché.
Evapco
Profil de l’entreprise
Fig. 01 — Evapcold LCR-P Penthouse
01 Présentation
The LCR-P is specifically designed to be roof mounted on the refrigerated space. Penthouse units are available with Pumped Recirculated Liquid (PRL) ammonia evaporators for low and medium temperature applications, or Direct Expansion (DX) evaporators for medium and high temperature applications.
01
Evapcold – LCR-P Penthouse Units have
- The capacity of 10 and 100 TR
- Room temperatures range from -20ºF to +70ºF
- Water-cooled or air-cooled condensing
- Hot gas defrost, air defrost, or no defrost
- PRL models are a great match for freezers and coolers
02
LCR-P Penthouse Units – Evapcold Advantages
- Very low ammonia charge of 3 to 6 lb/TR depending on model size
- Hot gas defrost on all low & medium temperature models: the most efficient defrost method and allows units to continue running while in defrost mode
- Very efficient and reliable evaporator operation with low 1.2:1 pumped liquid recirculation rate or DX for medium and high-temperature applications
- Personnel access to penthouse evaporators is separate from access to the machine room
- Insulated “Superfloor” under the machine room eliminates the need for a roofer to perform this work
- EVAPCO self-performs 100% of the packaging scope of work
03
Lower Energy Consumption
The Evapcold product can reduce a facility’s energy consumption and attain annual energy savings of up to 15% as a result of the following:
- Variable Speed Drives (VFD) on every compressor, NH3 pump, and condenser fan (for air-cooled models) and also optional on the evaporator fans
- Room temperature is directly connected to its own compressor suction, not a “house” suction that may be common to different room temperatures
- Evapcold packages eliminate refrigerant pressure drops associated with long piping runs
- Evapcold’s built-in software in conjunction with the supervisory control system provides superior energy management
All of the above add up to real energy savings over the course of a year compared to traditional ammonia systems. In addition, the LCR units consume significantly less energy than Freon systems.
02 Dossier technique
Caractéristiques
2 données · telles que publiées par Evapco
- Fluide frigorigène
- Ammonia
- Catégorie
- Systèmes
01Fluide frigorigène
1 entrée
- Refrigerant
- Ammonia
02Certification et marchés
1 entrée
- Region
- Africa, Asia, Australia & NZ, China, Europe, Global, Japan, North America, South America
Parlez de LCR-P Penthouse avec Evapco.
Envoyez votre demande à Evapco : demandez caractéristiques, tarifs et disponibilité pour votre projet.