Aller au contenu
Bêta

Voici le nouveau NaturalRefrigerants.com. Un problème technique ou de contenu ? Écrivez-nous à info@naturalrefrigerants.com.

Compact Kältetechnik GmbH

Compact Ejector

Compact Ejector is used to increase efficiency in CO₂ booster systems.

Cette page produit n’est pas encore disponible en français : l’original en anglais est affiché.

Compact Logo

Compact Kältetechnik GmbH

Profil de l’entreprise
Compact Enjector

Fig. 01 — Compact Enjector

01 Présentation

In conjunction with a high-pressure valve, three different types of gas and two types of liquid ejectors can be combined as desired.

01

Features

  • Efficiency increases of 15-30% possible (compare with a booster system with flash gas bypass)
  • Lower compressor capacity required (smaller or fewer number of compressors)
  • Can be individually tailored to each application and each performance level
  • Air conditioning and/or heat pump evaporator can be integrated
  • Extended running time of the parallel compressor even at lower outside temperatures
  • High reliability (no moving or rotating components)
  • Short payback period (depending on system size)

Function – Principle of operation
* c -Ejector uses the expansion work present in the refrigerant to suck in another partial flow and transport it to a higher pressure level.

The CO₂ emerging from the gas cooler at high pressure is accelerated in the motive nozzle. As a result, the static pressure drops. The flow emerging from the motive nozzle has a lower pressure than the suction pressure of the NK stage.

02

Either gas or liquid can be extracted from the suction side of the NK compressors.

Both partial streams mix in the mixing chamber.

03

In the diffuser, the flow is slowed down again, which causes a pressure increase to medium pressure level. After the diffuser, the mixture is fed into the medium pressure separator.

02 Dossier technique

Caractéristiques

8 données · telles que publiées par Compact Kältetechnik GmbH

Fluide frigorigène
CO₂
Max. working pressure
120bars

01Limites de fonctionnement

4 entrées

Max. working pressure
120bars
Test pressure
1.1 x 120 bar
Temperature medium
-50 °C … +150 °C
Temperature Ambient
-10 °C … +50 °C

02Fluide frigorigène

1 entrée

Refrigerant
CO₂

03Construction et dimensions

2 entrées

Material
Stainless steel 1.4301
Weight
1.3 kg

04Certification et marchés

1 entrée

Region
Europe
Compact Logo

Parlez de Compact Ejector avec Compact Kältetechnik GmbH.

Envoyez votre demande à Compact Kältetechnik GmbH : demandez caractéristiques, tarifs et disponibilité pour votre projet.

Partager